Head Office
 
 
Home
 
Tender Document
Broad Street Head Offices
April 1932
(pages 265 to 276)
 
ELECTRIC LIGHT AND POWER, BELLS, NEON LIGHTS,
CLOCKS, DICTAPHONE AND TELEPHONES.
ELECTRIC LIGHT AND POWER.
 
Add for attendance and facilities as described in General Preliminaries to Specialists in running conduit and wiring to the following.
(Perforations, chases etc., elsewhere measured).
Number
    251      Switch points
     52       Power points
    375      Light points
 
BUILDERS WORK IN CONNECTION.
Cut chase for conduit tube:-
Feet
8904 in brick walls
2760 in hollow block partition
1425 in hollow block floor
  295 in concrete casing
  180 in concrete ceiling
4190 in cement screeding
  108 in slab partition
 
Holes for conduit tube and make good:-
Number
  340 through 4½" wall
  191 through 9" wall
  125 through 14" wall
      6 through 4½" stone
      2 through 18" reinforced concrete wall
      4 through 24" reinforced concrete wall
  380 through hollow block partition
  899 through hollow block floor
     10 through slab partition
       7 through teak block flooring
       2 through deal skirting
     30 through hardwood skirting
 
Cut out and make good:-
Number
     15 in hardwood skirting for plug
       2 in tile for plug
       6 and pin end of brackets of main fuse board
   180 in brick wall for access box or sunk switch
     71 in hollow block partition for access or sunk switch
 
Run conduit and wiring to the following:-
Number
    25      Pushes for Electric Bells
    14      Pushes acting on three bells for Alarm Bells
      2      Tube letter signs "Birmingham Municipal Bank" 14" high
      1      Teak letter sign "Birmingham Municipal Bank" 24" high
 
KEEPALITE PLANT.
 
Add for attendance and facilities as described in General Preliminaries to Specialists in fixing small dynamo, storage batteries and conduit and wiring to the following:-
(perforations, chases etc. elsewhere measured)
Number
    22       Light points
 
WIRING TO CLOCKS.
 
Add for attendance and facilities as described in General Preliminaries to Specialists in running conduit and wiring to the following:-
(perforations, chases etc. elsewhere measured)
Number
    40        Clocks and equipment
 
BUILDERS WORK IN CONNECTION.
Cut chase for conduit tube:-
Feet
 525 in brick walls
   50 in hollow block partition
   45 in cement floated bed  
   29 in concrete walling
   12 in solid concrete casing to steel joist
    80 in surface of patent hollow block floor
    60 in soffite patent hollow block floor
 
Holes for conduit tube and make good:-
Number
      8 through 4½" wall
    10 through 9" wall
      6 through 14" wall
      3 through 18" wall
      6 through 3" hollow block partition
      3 through 2½" slab partition     
     15 through 5" hollow block floor
       8 through 5½" hollow block floor
 
CLOCKS.
 
Fix the following and in addition plug finished wall surfaces where required and make good and for insertion clocks cut out in the finished wall surfaces described neatly make good and reinstate around the item:-
Number
     4        6" Wall clock with hardwood case to plastered brick wall
     1        9" Ditto with do.   to brick faced wall
     1        9" Ditto with do.   to "Keene's" plastered brick walls
     2        9" Ditto with do.   to plastered hollow block partition
     3        9" Ditto with Bakelite case to plastered brick wall
     1     12"  Ditto with do.   to brick faced wall
     1     12"  Ditto with hardwood case to plastered brick walls
     1      Special plate glass clock suspended from concrete casing to steel girder finished with enriched fibrous plaster
     1      Master clock in Walnut case to plastered hollow block partition
     1      Trickle charge unit in cast iron case and fuse board to plastered brick wall
    16     6" Insertion pattern clock in plastered brick wall
     1      6" Ditto do.   in "Calime" plastered do.
     2      6" Ditto do.   in plastered hollow block partition
     1      6" Ditto do.   in "Stuc" plastered concrete wall
     1      9" Insertion pattern clock in "Calime" plastered brick wall
     1      9" Ditto do.   in marble faced brick wall
     1      12" Ditto do. in plastered brick wall
     1      16" Ditto do. in plastered brick wall
 
DICTAPHONES.
 
Run conduit and wiring to the following:-
Number
      8       Points
  Feet
   184     Cut chase in brick wall/cement floated bed/in surface of patent hollow block floor for conduit.
 
TELEPHONES.
 
Run conduit and wiring to the following:-
Number
      27      Telephone Points
  Feet
   823     Cut chase for conduit in brick wall/hollow block partition/cement floated bed/concrete walling/solid concrete casing to steel
               joist/surface of patent hollow tiles/soffite of patent hollow tiles
 
Tender Document
 
LIFTS:
pages 277 to 283