Tender Document
Broad Street Head Offices
April 1932
(pages 304 to 316)
 
VENTILATION.
Install the following:
 
Number
      1        Plenum fan inlet and extract apparatus with scrubbers, pumps, motors, etc., sheet metal trunking, wall fans, etc.
 
Add for providing any water etc., necessary for testing purposes.
 
BUILDERS WORK IN CONNECTION.
 
The following to be executed in accordance with the instructions of the Engineers:-
 
CONCRETOR.
Yards
  11     Cement concrete 1-2-4 bed 5" thick under motors floated smooth in cement
                 104' 0" Run. Fair cement face to edge and arris and angles.
 
  14    Precast cement concrete 1-2-4 roof slab 3" thick reinforced with and include approved stout reinforcing lathing and hoist and
                   fix on roof over Second Floor.
 
THE FOLLOWING TO BE IN CEMENT CONCRETE COMPOSED OF
one  part cement, with 3% of Toxement or other approved waterproofer,
mixed in accordance with maker's instructions, two parts sand and three
parts ¾" washed granite chippings:-
Yards
  98     Cement concrete 1-2-3 floor of duct 6" thick with smooth floated finish.
    3     Ditto 1-2-3 ditto 6" thick laid to falls with ditto.
  57     Ditto 1-2-3 ditto sloped from 1" at both sides to 9" thick at centre and laid on concrete bed
                 (elsewhere measured) with smooth floated finish.
 
THE FOLLOWING TO BE IN CEMENT CONCRETE composed of
one  part cement, two parts sand and three parts ¾" washed granite chippings:-
Yards
  51     Precast cement concrete 1-2-3 cover to duct 3" thick reinforced with and include approved stout
                reinforcing lathing and bed and joint in cement.
    5     Ditto 1-2-3 ditto 3" thick circular on plan to quick sweep ditto and ditto.
                No. 7.  Rebated perforation 18" x 12"
                No. 2.  Ditto 18" x 18"
  61     Precast cement concrete 1-2-3 cover to duct 6" thick reinforced with and include approved stout
               reinforcing lathing and bed and joint in cement.
                 No. 4. Rebated perforation 24" x 24".
  58     Ditto 1-2-3 ditto 3" thick at sides for 3" wide where resting on walls and with soffits sloped from
               both sides to 9" thick at centre.
                 No. 4.  Rebated perforation 24" x 24".
 
BRICKLAYER.
Yards
  113     Brick on edge 3" walling in cement mortar to carry duct cover below Basement, done after
                 main walling is built.
 
SMITH AND FOUNDER.
 
UNLOAD, STORE, PROTECT, HOIST AND FIX ONLY to
wood grounds (elsewhere measured) the
following and return empties:-
Number
    4       Bronze grating 4' 0" x 1' 3"
 
Tender Document
 
GLAZIER: